Oscyloskop cyfrowy FNIRSI 1014D 2w1 generator sygnału
- Watch the product:
- Add feedback:
- Code: INN_53786
- Manufacturer: FNIRSI
- Availability: 1 working day
-
- 163.17 EUR
- szt.
BUY NOW AND CREATE YOUR DREAM HOME. DO IT NOW IN 3 SIMPLE STEPS.
Your purchases will be delivered by DPD Courier.
You can pay for your purchases with credit card or bank transfer using safe PayU system or bank transfer.
You've made a good choice. However, if you return the product within 14 days, you'll receive a full refund.
Oscyloskop 2w1 FNIRSI 1014D generator sygnału
The FNIRSI 1014D is a compact digital oscilloscope designed for electronics repair shops, research and development departments, technical education, and hobbyists. It allows for simultaneous signal analysis and generation, significantly expanding the range of applications for system diagnostics, prototype testing, and learning to work with waveforms. The device has two 1 MΩ input channels and supports a bandwidth of 100 MHz at a sampling rate of 1 GSa/s. The 7-inch LCD screen with 800 x 480 px resolution makes it easy to use. Auto analysis, FFT, XY mode, and cursor recording are supported. 1 GB of internal memory allows users to store up to 1000 waveforms and 1000 screenshots, and data can be easily exported to a computer via USB.
Quick signal analysis
The high sampling rate of 1GSa/s and the bandwidth of 100MHz enable detailed analysis of analog and digital signals. This allows the device to capture even short-term waveform anomalies. Trigger modes include Auto, Single, and Normal, allowing the capture of both interference pulses and regular analog signals, such as sinusoidal ones.
Built-in DDS generator
The integrated DDS signal generator supports 14 standard waveforms ( among others (e.g., sine, square, sawtooth, triangle), with the ability to precisely adjust the frequency in 1 Hz increments. This solution allows for the generation of signals with precise parameters for testing and simulation. The output frequency range reaches up to 10 MHz (for a sine wave), allowing for testing a wide range of electronic and signal systems.
Waveform Capture Function
The "capture output" function allows you to record part or all of the actual oscilloscope waveform as the generator's output. The ability to record up to 1000 custom signals increases flexibility in testing and analysis. This feature distinguishes the FNIRSI 1014D from traditional arbitrary waveform generators, which rely solely on manual signal setting.
Surge Protection
The integrated high-voltage protection module allows you to safely measure signals up to 400V (with a 10x probe), reducing the risk of damage to the device when measuring in mains-powered systems. The protection function operates automatically, so accidental use of the probe without switching to 10x does not risk damage to the equipment.
Highly readable display
The 7" color TFT screen with a resolution of 800x480 pixels provides a clear presentation of waveforms. Auto mode and an intuitive interface allow you to quickly obtain a signal image without the need for manual adjustments. Thanks to an intelligent detection algorithm, the device automatically adjusts the trigger level even for waveforms with multiple edges or a so-called dead zone. This solution saves time and prevents interpretation errors. The oscilloscope allows you to save up to 1000 screenshots and 1000 waveforms in its 1 GB internal memory. Data can be viewed in thumbnail form, facilitating quick preview and selection. The interface allows you to enlarge, delete, and export recordings without having to exit review mode.
Signal Analysis Features
The built-in FFT function and XY waveform display mode allow you to analyze harmonic components and compare the amplitudes and phase shifts of two signals. These are useful tools for diagnosing electronic systems. Additionally, the manual cursor measurement mode allows you to read the peak value and frequency without having to recalculate the scale, increasing the precision of analysis even with noisy waveforms. The device uses a special algorithm for decoding the signal from the knob, eliminating the problem of erroneous readings caused by oxidation or wear of the mechanism. Even if the encoder is damaged, the oscilloscope continues to function correctly.
Included:
- FNIRSI 1014D 2-in-1 Oscilloscope
- 100 MHz Probe x2
- USB Charger
- User Manual
| Manufacturer | FNIRSI |
|---|---|
| Model | 1014D |
| Channels | 2 |
| LCD Screen Size | 7 inches |
| LCD Resolution | 800 × 480 |
| Display Technology | LCD |
| Bandwidth Response | 100 MHz |
| Sampling Rate | 1 GSa/s |
| Highest Test Voltage | 1X: 40V, 10X: 400V |
| Cursor | XY Position Y Trigger |
| Roll Mode | Supported |
| Auto Calibration | Supported |
| Waveform Storage | 1000 Images + 1000 Waveforms |
| Waveform Management | Supported |
| Voltage Accuracy | ±5% |
| Rise Time | < 3 ns |
| Memory Depth | 240 Kbit |
| Input Resistance | 1 MΩ |
| Sensitivity | 50 mV ~ 500 V |
| Time Base | 50 s ~ 10 ns |
| Trigger Mode | Single / Normal / Auto |
| Trigger Edge | Rising / Falling |
| Coupling | AC / DC |
| Accuracy Frequency | ±0.01% |
| Parameters | 12 types |
| Generator | 14 types |
| Capture Output | Supported |
| Expansion | USB Export |
| Power Supply | 5V 2A / 3A / 4A |
| Dimensions | 310 × 145 × 70 mm |
Ask a question about the product. Our team will be happy to provide a detailed answer to your inquiry.